Slot Heat Exchanger Regenerator and Heater
M28
Revised: 04/21/2019
When : d=0.03mm
19K,0.1MPa He
Heat transfer coefficient ≈ 100mW /(cm . K)
¡@
¡@
Substitute ?
¡@
¡@
¡@
¡@
¡@
¡@
M28A
¡@
Slot Heat Exchanger type Heater
Pressure (Fluid) Velocity (Fluid)
Temperature (Fluid) Temperature (Solid)
¡@
Slot d=0.3mm (Length=9cm, High=8mm, Number of Slots = 25)
Temperature=610K, dTemperature=170K, Pressure=0.17MPa Air
Air(specific heat capacity 610K) S = 1310 J/Kg.K
Fluid Speed = 130 m/s
¡@
PV=M*R*T==>P(Pa)=(M/V)*R*T=Density*R*T
Density=P/RT , Where R=287.05 J/Kg.K
Density(Air)=170000 / (287.05 * 610) = 0.971 Kg/m^3
¡@
M(air)=V * Density = (0.09*0.008*0.0003)*0.971 = 0.00000021 Kg
¡@
Heat Q = M * S * dT = 0.00000021 * 1310 * 170 = 0.0468 J
¡@
Time (Fluid pass Heater) = 0.09 / 130 = 0.000692 sec
¡@
Power = dQ/dT = 0.0468 / 0.000692 = 67.6W
¡@
P = dQ/dT = K * A * dt / L
Heat transfer coefficient K = P * L / (A *dt)
K = 67.6 * 0.0003 / (0.09 * 0.008 * 170) = 0.166 W /(m . K)
Single slot P = dQ/dT = K.A.dt / L= 0.166*(0.09*0.008)*170/0.0003 ≈ 67W
Total Heat transfer = 67 * 25 = 1675W (Ideal case)
¡@
Slot Heat Exchanger Regenerator
¡@
Piston
¡@
Cylinder
¡@
Connecting Rod and Crankshaft
¡@
¡@
Alpha Double Action Type - M28
¡@
¡@
¡@
¡@
¡@
¡@
¡@
¡@